AIR PRODUCTS -- HYDROGEN CHLORIDE -- 6830-00N030950
=====================  Product Identification  =====================

Product ID:HYDROGEN CHLORIDE
MSDS Date:10/01/1993
FSC:6830
NIIN:00N030950
=== Responsible Party ===
Company Name:AIR PRODUCTS
Address:7201 HAMILTON BLVD
City:ALLENTOWN
State:PA
ZIP:18195-1501
Country:US
Info Phone Num:800-752-1597
Emergency Phone Num:800-752-1597
CAGE:00742
=== Contractor Identification ===
Company Name:AIR PRODUCTS AND CHEMICALS INC
Address:7201 HAMILTON BLVD
Box:City:ALLENTOWN
State:PA
ZIP:18195-1501
Country:US
Phone:800-345-3148/ 800-752-1597
CAGE:00742

=============  Composition/Information on Ingredients  =============

Ingred Name:ING 14:RECORDS. VISUALLY INSPECT STORED CYLS ON ROUTINE
    BASIS, @ LST WEEKLY, FOR ANY INDICATION OF LEAKAGE/OTHER(ING 16)
RTECS #:9999999ZZ

Ingred Name:ING 15:PROBS. CAUT:CONT W/COLD, EVAP LIQ ON GLOVES/SUIT MAY
    CAUSE CRYOGENIC BURNS/FROSTBITE. COLD TEMPS MAY ALSO(ING 17)
RTECS #:9999999ZZ

Ingred Name:ING 16:CAUSE EMBRITTLEMENT OF PPE MATL RSLTG IN BREAKAGE &
    EXPOS. POIS GAS, CORR. CYLS SHOULD BE TRANSPORTED IN (ING 18)
RTECS #:9999999ZZ

Ingred Name:ING 17:SECURE UPRIGHT POSITION IN WELL VENTED TRUCK FOR
    SHIPPING. NEVER TRANSPORT IN PASSENGER COMPARTMENT OF A (ING 19)
RTECS #:9999999ZZ

Ingred Name:ING 18:VEHICLE. DO NOT DRAG, ROLL/SLIDE CYL. USE SUITABLE
    HANDTRUCK DESIGNED FOR CYL MOVEMENT. NEVER ATTEMPT TO (ING 20)
RTECS #:9999999ZZ

Ingred Name:ING 19:LIFT CYL BY ITS CAP. SECURE CYLS AT ALL TIMES WHILE
    IN USE. USE PRESS REDUCING REGULATOR/SEPARATE CONTROL(ING 21)
RTECS #:9999999ZZ

Ingred Name:ING 20:VALVE TO SAFELY DISCHARGE GAS FROM CYL. USE CHECK
    VALVE TO PVNT REVERSE FLOW INTO CYL. NEVER APPLY FLAME/(ING 22)
RTECS #:9999999ZZ

Ingred Name:ING 21:LOCALIZED HEAT DIRECTLY TO ANY PART OF CYL. DO NOT
    ALLOW ANY PART OF CYL TO EXCEED 125F(52C). HIGH TEMP (ING 23)
RTECS #:9999999ZZ

Ingred Name:ING 22:MAY CAUSE DMG TO CYL &/OR PREMATURE FAILURE OF PRESS
    RELIEF DEVICE WHICH WILL RSLT IN VENTING OF CYL (ING 24)
RTECS #:9999999ZZ

Ingred Name:ING 23:CONTENTS. IF USER EXPERS ANY DFCLTY OPERATING CYL
    VALVE, DISCONTINUE USE & CONT SUPPLIER. USE ADJUSTABLE (ING 25)
RTECS #:9999999ZZ

Ingred Name:ING 24:STRAP-WRENCH TO REMOVE OVER-TIGHT OR RUSTED CAPS.
    CONTACT NEHC FOR MORE SPECIFIC INFORMATION .
RTECS #:9999999ZZ

Ingred Name:HYDROCHLORIC ACID  (SARA 302/313) (CERCLA)
CAS:7647-01-0
RTECS #:MW4025000
Fraction by Wt: >99%
OSHA PEL:5 PPM, C
ACGIH TLV:5 PPM, C
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:VOLATILE ORGANIC COMPOUNDS (SCAQMD RULE): NONE.
RTECS #:9999999VO

Ingred Name:SUPDAT:CONCS CAN CAUSE INFLAMM (CHEM PNEUM) & FLUID
    BUILD-UP (PULM EDEMA) IN LUNGS/SPASM OF LARYNX WHICH MAY RSLT(ING
    4)
RTECS #:9999999ZZ

Ingred Name:ING 3:IN DEATH. LETHAL CONCENTRATION FOR HYDROGEN CHLORIDE:
    LC50 = 3120 PPM (1 HR, RAT).
RTECS #:9999999ZZ

Ingred Name:FIRST AID PROC:TIMES. SEEK MED ATTN IMMED. SKIN:FLUSH
    W/WATER FOR 15 MINS. REMOVE CONTAM CLTHG. APPLICATIONS OF (ING 6)
RTECS #:9999999ZZ

Ingred Name:ING 5:ICE WATER COMPRESSES FOR 30 MINS AFTER FLUSHING MAY
    HELP LIM EXTENT OF BURN. NOTE TO MD:BRONCHOSPASM MAY BE(ING 7)
RTECS #:9999999ZZ

Ingred Name:ING 6:TREATED W/USE OF BRONCHODILATOR SUCH AS ALBUTEROL &
    ANTICHOLINERGIC INHALANT SUCH AS ATROVENT.
RTECS #:9999999ZZ

Ingred Name:SPILL PROC:INERT SYS BEFORE ATTEMPTING REPAIRS. DO NOT RELS
    LG AMTS OF PROD TO ATM. THIS PROD DOES NOT CNTN ANY (ING 9)
RTECS #:9999999ZZ

Ingred Name:ING 8:CLASS I OR II OZONE DEPLETING CHEMS. PROD NOT LISTED
    AS MARINE POLLUTANT BY DOT (40 CFR). CERCLA REQS (ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 8:NOTIFICATION TO THE NRC OF RELS OF QTYS OF HAZ
    SUBSTANCES EQUAL TO/GREATER THAN RQ IN 40 CFR 302.4. RQ:5000 LBS.
RTECS #:9999999ZZ

Ingred Name:WASTE DISP METH:TRAP IN DISCHARGE LINE TO PVNT CAUSTIC SOLN
    FROM DRAWING BACK THRU LINES. UNUSED PROD/EMPTY CYL:(ING 12)
RTECS #:9999999ZZ

Ingred Name:ING 11:RETURN CYL & UNUSED PROD TO SUPPLIER. DO NOT ATTEMPT
    TO DISP OF UNUSED PROD. ENSURE CYL VALVE IS PROPERLY(ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12:CLSD, VALVE OUTLET CAP HAS BEEN REINSTALLED & VALVE
    PROT CAP IS SECURED BEFORE SHIPPING CYLINDER.
RTECS #:9999999ZZ

Ingred Name:OTHER PREC:EMPTY CYLS. AVOID EXCESS INVENTORY & STOR TIME.
    USE FIRST-IN FIRST-OUT SYS. KEEP ACCURATE INVENTORY (ING 15)
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHAL:PROD IS CORR & IRRIT TO RESP
    TRACT & MUC MEMBS. EXCESSIVE EXPOS TO CONCS ABOVE CEILING LIM MAY
    RSLT IN CHEM PNEUM (INFLAMM), PULM HEMORR (BLEEDING) & EDEMA (FLUID
    BUILD UP). EYE CONT:IRRIT &/OR  BURNS TO CORNEA THAT MAY LEAD TO
    VISIONIMPAIRMENT/LOSS. SKIN CONT:BURN SIMILAR TO ONE THAT IS CAUSED
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:BY INORG ACIDS. SYMPS:IRRIT &/OR BURNS
    OF EXPOS AREAS. COUGH, IRRIT IN THROAT, NOSE & EYES. CONCS OF 5 PPM
    ARE USUALLY SUFFICIENT TO PRDCE ONE/MORE OF THESE SYMPS. TARGET
    ORGS:AIRWAY, LUNGS,  EYES & SKIN. TOX INFO:PROD IS TOX, CAUSING SEV
    IRRIT OF UPPER RESP TRACT UPON INHAL & IRRIT OF EYES & SKIN ON
    (SUPDAT)
Medical Cond Aggravated by Exposure:ASTHMA, EMPHYSEMA OR OTHER
    RESPIRATORY DISEASES.

=======================  First Aid Measures  =======================

First Aid:INGEST:CALL MD IMMED. INHAL:MOVE EXPOS PERS TO UNCON AREA. IF
    NOT BRTHG, GIVE ARTF RESP. IF BRTHG IS DFCLT, GIVE OXYG. SEEK
    PROMPT MED ATTN & CONTINUE W/ADMIN OF OXYG. IF AIRWAY OBSTRUCTION
    OCCU RS PLACEMENT OF ARTIF AIRWAY, BY EMER MED TECHNICIANS, MAY BE
    NEC. EYES:FLUSH W/WATER FOR MIN OF 15 MINS. HOLD LIDS OPEN
    W/FINGERS TO ASSURE COMPLETE FLUSHING. THIS MAY HAVE TO BE RPTD
    SEVERAL (ING 5)

=====================  Fire Fighting Measures  =====================

Flash Point:NONFLAMMABLE
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP . IF
    POSS W/OUT RISK, MOVE CYLS AWAY FROM FIRE AREA. KEEP CYLS COOL
    W/WATER SPRAY UNTIL WELL AFTER FIRE IS OUT.
Unusual Fire/Explosion Hazard:RUNOFF FROM FIRE FIGHTING MAY BE CONTAM;
    CHECK PH. CYLS EXPOS TO HIGH HEAT/FLAME MAY VENT RAPIDLY & MAY
    RUPTURE VIOLENTLY. MOST CYLS ARE DESIGNED TO (SUPDAT)

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE ALL PERS FROM AFFECTED AREA. INCR
    VENT TO RELS AREA & MONITOR OXYG LEVEL. USE APPROP PROT EQUIP
    (NIOSH APPRVD SCBA). IF LEAK IF FROM CYL/CYL VALVE CALL MFR'S EMER
    TELEPHONE #. IF LEAK IS IN U SER'S SYS CLOSE CYL VALVE, VENT PRESS
    &(ING 8)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STOR AREA TEMPS SHOULD NOT EXCEED
    125F(52C) & SHOULD BE FREE OF COMBUST MATLS. STOR SHOULD BE AWAY
    FROM HEAVILY TRAVELED AREAS & EMERGENCY EXITS.
Other Precautions:AVOID AREAS WHERE SALT/OTHER CORR MATLS ARE PRESENT.
    SECURE CYLS IN UPRIGHT POSITION & STORE IN WELL-VENTED AREA PROT
    FROM WEATHER. VALVE PROT CAPS & VALVE OUTLET SEALS SHOULD REMAIN ON
    CYLS NOT CONNE CTED FOR USE. SEPARATE FULL FROM(ING 14)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH APPROVED SELF CONTAINED BREATHING
    APPARATUS SHOULD BE AVAILABLE.
Ventilation:PROVIDE VENTILATION &/OR LOCAL EXHAUST TO PREVENT
    ACCUMULATION OF HYDROGEN CHLORIDE CONCENTRATIONS ABOVE 5 PPM.
Protective Gloves:LEATHER GLOVES FOR HNDLG CYLS. (SUPDAT)
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS &(SUPDAT)
Other Protective Equipment:ANSI APPRVD EYE WASH FOUNTAIN & DELUGE
    SHOWER . SFTY SHOES FOR HNDLG CYLS. SPLASH SUIT WHEN CONNECTING,
    (SUPDAT)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ:VENT CONTENTS WHEN EXPOS TO ELEVATED TEMPS FOUND IN FIRE
    SITUATIONS. PROT GLOVES:ACID RESIST GLOVES WHEN CONNECTING,
    DISCONNECTING/ OPENING CYLS. EYE PROT:FULL LGTH FSHLD . OTHER PROT 
    EQUIP:DISCONNECTING/OPENING CYLS. FULL-PROT CHEM RESIST SUIT SHOULD
    BE AVAIL. EFTS OF OVEREXP:CONT. INHAL OF HIGH(ING 3)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:-121F,-85C
Melt/Freeze Pt:M.P/F.P Text:-174F,-114C
Vapor Pres:613 PSIG
Spec Gravity:1.266 (AIR=1)
Solubility in Water:0.823
Appearance and Odor:COLORLESS GAS THAT FUMES WHITE; SHARP, SUFFOCATING,
    ACIDIC ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
MOISTURE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISP MUST BE I/A/W FED, STATE & LOC REGS . SM
    AMTS OF PROD MAY BE DISP OF BY SLOWLY DISCHARGING GAS INTO
    SCRUBBER/OTHER SUITABLE VESSEL CNTNG APPROX 15% SODIUM
    HYDROXIDE/OTHER ALKALI & WATER. IT	IS NEC TO PLACE REVERSE-FLOW
    CHECK-VALVE/(ING 11)

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.