EM DIAGNOSTICS SYSTEMS DIV OF EM INDUSTRIES -- ZENKER FIXATION FLUID, 7835 -- 6810-00N071945
===================== Product Identification ===================== Product ID:ZENKER FIXATION FLUID, 7835 MSDS Date:03/29/1995 FSC:6810 NIIN:00N071945 === Responsible Party === Company Name:EM DIAGNOSTICS SYSTEMS DIV OF EM INDUSTRIES Address:480 DEMOCRAT RD Box:70 City:GIBBSTOWN State:NJ ZIP:08027 Country:US Info Phone Num:609-423-6300 Emergency Phone Num:800-424-9300 (CHEMTREC) CAGE:JO100 === Contractor Identification === Company Name:E M SCIENCE DIV OF E M INDUSTRIES INC Address:480 DEMOCRAT ROAD Box:70 City:GIBBSTOWN State:NJ ZIP:08027 Country:US Phone:800-222-0342/609-423-6300 CAGE:63612 Company Name:EM DIAGNOSTICS SYSTEMS INC Address:480 DEMOCRAT RD Box:70 City:GIBBSTOWN State:NJ ZIP:08027 Country:US Phone:609-423-6300 CAGE:JO100 ============= Composition/Information on Ingredients ============= Ingred Name:DICHROMIC ACID, DIPOTASSIUM SALT; (POTASSIUM DICHROMATE) (SARA 313) (CERCLA) CAS:7778-50-9 RTECS #:HX7680000 Fraction by Wt: 2.5% OSHA PEL:C 0.1 MG (CRO3)/M3 ACGIH TLV:0.5 MG (CR)/M3, A4 EPA Rpt Qty:10 LBS DOT Rpt Qty:10 LBS Ingred Name:MERCURY (II) CHLORIDE; (MERCURIC CHLORIDE) (SARA 302/313) (CERCLA) CAS:7487-94-7 RTECS #:OV9100000 Fraction by Wt: 4.9% OSHA PEL:0.1 MG (HG)/M3 ACGIH TLV:0.025 MG (HG)/M3, S ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO Health Hazards Acute and Chronic:ACUTE: THIS MIXTURE CONTAINS MERCURIC CHLORIDE. MERCURY COMPOUNDS ARE LETHAL WHEN INGESTED AND TOXIC WHEN ABSORBED THROUGH SKIN. CAN CAUSE EYE IRRITATION. CHRONIC: MERCURY APPEARS ON THE NAVY OCCUPATI ONAL CHEMICAL REPRODUCTIVE HAZARDS LIST. SEEK CONSULTATION FROM APPROPRIATE HEALTH PROFESSIONALS (EFTS OF OVEREXP) Explanation of Carcinogenicity:POTASSIUM DICHROMATE: IARC MONO, VOL 49, PG 149, 1990: GROUP 1. NTP 7TH ANNUAL RPT ON CARCINS, 1994: KNOWN TO BE CARCIN. Effects of Overexposure:HLTH HAZ: CONCERNING LATEST HAZARD LIST INFORMATION AND SAFE HANDLING AND EXPOSURE INFORMATION . Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER. ======================= First Aid Measures ======================= First Aid:EYES: FLUSH WITH POTABLE WATER FOR AT LEAST 15 MINUTES. SEE MD . SKIN: FLUSH WITH COPIOUS AMOUNTS OF WATER. SEE MD . INHALATION: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE OXYGEN OR ARTI FICIAL RESPIRATION) . INGESTION: CALL MD IMMEDIATELY . ===================== Fire Fighting Measures ===================== Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE . Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE EQUIPMENT . Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER. ================== Accidental Release Measures ================== Spill Release Procedures:WEAR SUITABLE PROTECTIVE EQUIPMENT LISTED UNDER CONTROL MEASURES SECTION. CONTAIN THE SPILL AND ELIMINATE ITS SOURCE, IF THIS CAN BE DONE WITHOUT RISK. SWEEP UP OR ABSORB SPILL AND CONTAINERIZE FOR PR OPER DISPOSAL. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER. Other Precautions:NONE SPECIFIED BY MANUFACTURER. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN . Ventilation:NONE SPECIFIED BY MANUFACTURER. Protective Gloves:IMPERVIOUS GLOVES . Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES . Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING ANSI DESIGN CRITERIA . Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health NONE SPECIFIED BY MANUFACTURER. ================== Physical/Chemical Properties ================== Solubility in Water:SOLUBLE Appearance and Odor:LIQUID ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES NONE SPECIFIED BY MANUFACTURER. Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER. Hazardous Decomposition Products:MAY GIVE OFF TOXIC FUMES. ==================== Disposal Considerations ==================== Waste Disposal Methods:ALWAYS CONTACT A PERMITTED WASTE DISPOSER (TSD) TO ASSURE COMPLIANCE WITH ALL CURRENT LOCAL, STATE AND FEDERAL REGULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.