RHONE-POULENC BASIC CHEMICALS CO -- SULFUR DIOXIDE -- 6830-00N038431
=====================  Product Identification  =====================

Product ID:SULFUR DIOXIDE
MSDS Date:08/23/1991
FSC:6830
NIIN:00N038431
=== Responsible Party ===
Company Name:RHONE-POULENC BASIC CHEMICALS CO
Address:1 CORPORATE DR
Box:881
City:SHELTON
State:CT
ZIP:06484
Country:US
Info Phone Num:203-925-3300
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:RHNEP
=== Contractor Identification ===
Company Name:RHONE-POULENC BASIC CHEMICAL CO
Address:1 CORPORATE DR
Box:881
City:SHELTON
State:CT
ZIP:06484
Country:US
Phone:203-925-3300
CAGE:RHNEP
Company Name:RHONE-POULENC INC.
Address:297 JERSEY AVENUE
Box:City:NEW BRUNSWICK
State:NJ
ZIP:08901
Country:US
Phone:203-925-3300/800-424-9300(CHEMTREC)
CAGE:55693

=============  Composition/Information on Ingredients  =============

Ingred Name:ING 8:IF BRTHG DFCLT OR IRRIT DEVELOPS, GET MD. EYE:IMMED
    FLUSH W/PLENTY OF WTAER FOR AT LEAST 15 MINS USING (ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9:AN EYE WASH FOUNTAIN IF AVAIL. LIFT UPPER/LOWER LIDS
    & RINSE WELL UNDER THEM. GET MD. NOTE TO MD:NO (ING 11)
RTECS #:9999999ZZ

Ingred Name:ING 10:SPECIFIC ANTIDOTE AVAIL. ALL TREATMENTS SHOULD BE
    BASED ON OBSERVED SIGNS/SYMPS OF DISTRESS IN PATIENT. (ING 12)
RTECS #:9999999ZZ

Ingred Name:ING 11:CONSIDERATION SHOULD BE GIVEN TO POSS THAT OVEREXP
    TO MATLS OTHER THAN THIS PROD MAY BE OCCURED.
RTECS #:9999999ZZ

Ingred Name:SPILL PROC:DIOXIDE IS PRESENT. NEVER APPLY WATER TO A
    SULFUR DIOXIDE LEAK. WATER CAUSES SULFUR DIOXIDE TO BE (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13:MORE CORROSIVE. A LEAKING SULFUR DIOXIDE CNTNR
    SHOULD BE SHIFTED SO THAT GASEOUS RATHER THAN LIQ MATL (ING 15)
RTECS #:9999999ZZ

Ingred Name:ING 14:WILL ESCAPE.. A SMALL LIQ SPILL OR LEAK CAN BE
    HANDLED ROUTINELY BY PASSING SULFUR DIOXIDE THRU AN (ING 16)
RTECS #:9999999ZZ

Ingred Name:ING 15:ALKALINE NEUTRALIZING SOLN. ONE POUND OF SULFUR
    DIOXIDE IS EQUIVALENT TO ABOUT 2 POUNDS OF LIME OR ONE & (ING 17)
RTECS #:9999999ZZ

Ingred Name:ING 16:A HALF POUNDS OF CAUSTIC SODA. LRG SPILLS SHOULD BE
    HANDLED ACCORDING TO PREDETERMINED PLAN. FOR ASSIST  (ING 18)
RTECS #:9999999ZZ

Ingred Name:ING 17:IN DEVELOPING A PLAN, CONTACT THE TECHNICAL SERVICE
    DEPARTMENT (1-800-642-4200).
RTECS #:9999999ZZ

Ingred Name:SULFUR DIOXIDE  (SARA III)
CAS:7446-09-5
RTECS #:WS4550000
Fraction by Wt: 100%
OSHA PEL:5 PPM/5 STEL
ACGIH TLV:2 PPM/5 STEL; 9293

Ingred Name:MATLS TO AVOID:CHLORINE DIOXIDE. CORRODES ALUMINUM.
RTECS #:9999999ZZ

Ingred Name:EFTS OF OVEREXP:LIKE RXNS FOLLOWING EXPOS TO RELATIVELY LOW
    LEVELS OF SULFUR DIOXIDE. SKIN:LIQ CAUSES BURNS (ING 4)
RTECS #:9999999ZZ

Ingred Name:ING 3:(FROSTBITE). EYE:LIQUID CAUSES BURNS. GAS IS SEVERELY
    IRRITATING. REPEATED EXPOS OF ANIMALS TO SULFUR (ING 5)
RTECS #:9999999ZZ

Ingred Name:ING 4:DIOXIDE CAN PRODUCE A THICKENING OF THE MUCOUS LAYER
    IN TRACHEA & AN INCR IN GOBLET CELLS & MUCOUS GLANDS (ING 6)
RTECS #:9999999ZZ

Ingred Name:ING 5:SIMILAR TO CHANGES OBSERVED IN HUMAN CHRONIC
    BRONCHITIS.
RTECS #:9999999ZZ

Ingred Name:FIRST AID PROC:LEAST 15 MINS, WHILE REMOVING CONTAM
    CLTHG/SHOES. DO NOT ATTEMPT TO NEUTRALIZE W/CHEM AGENTS. (ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 7:GET MD IMMED. DISCARD ANY CONTAM CLTHG/SHOES.
    INHAL:MOVE TO FRESH AIR. IF NOT BRTHG GIVE CPR OR ARTF RESP.(ING 9)
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE POISONING FROM SULFUR DIOXIDE IS
    RARE BECAUSE THE GAS IS EASILY DETECTED. IT IS SO IRRITATING THAT
    CONTACT CANNOT BE TOLERATED. SYMPS INCL COUGHING, HOARSENESS,
    SNEEZING, TEARING, & BRTHG DFCLTY . HOWEVER, WORKERS WHO CANNOT
    ESCAPE VERY HIGH ACCIDENTAL EXPOS MAY SUFFER SEVERE PULM DMG WHICH
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:CAN BE FATAL. INGEST:SWALLOWING LIQ
    SULFUR DIOXIDE WILL BURN MOUTH, ESOPHAGUS, & STOMACH DUE TO
    FREEZING EFT OF LIQ. INHAL:BRTHG SULFUR DIOXIDE GAS WILL IRRITATE
    EYES, THROAT & UPPER RESP SYS . ACUTE OVEREXP MAY RSLT IN DEATH BY
    SUFFOCATION. A SMALL PERCENTAGE OF PERS W/ASTHMA MAY SUFFER SEVERE
    ASTHMA-(ING 3)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:REMOVE PATIENT FROM IMMED SOURCE OF EXPOS & ASSURE THAT INDIV
    IS BRTHG. IF NOT BRTHG USE ARTF RESP. GET MD.  INGEST:IF CONSCIOUS
    & ALERT, GIVE 2 OR MORE GLASSES OF WTER OR MILK TO DRINK. DO NOT
    INDUCE  VOMIT. IF VOMIT OCCURS, GIVE FLUIDS AGAIN. DO NOT GIVE
    ANYTHING BY MOUTH TO UNONC/CONVL PERS. GET MD. SKIN:WASH ALL
    AFFECTED AREAS W/PLENTY OF SOAP & WATER WHILE UNDER SAFETY SHOWER
    FOR AT (ING 7)

=====================  Fire Fighting Measures  =====================

Flash Point:NOT COMBUSTIBLE
Lower Limits:NONE
Upper Limits:NONE
Extinguishing Media:NOT COMBUSTIBLE. USE APPROPRIATE EXTINGUISHING
    MEDIA FOR MATERIAL THAT IS SUPPLYING FUEL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL PROT
    EQUIP . EVAC RESIDENTS WHO ARE DOWNWIND OF FIRE. PVNT UNAUTHORIZED
    ENTRY TO FIRE AREA. DIKE AREA TO (SUPDAT)
Unusual Fire/Explosion Hazard:KEEP FIRE-EXPOSED CONTAINERS COOL WITH
    WATER SPRAY.

==================  Accidental Release Measures  ==================

Spill Release Procedures:PERS INVOLVED IN CLEANING UP SPILL OR STOPPING
    LEAK SHOULD WEAR GAS MASKS &/OR SCBA & IMPERVIOUS PROT CLTHG. SMALL
    LEAKS MAY BE READILY LOCATED BY SPRAYING POTNTL LEAK AREA
    W/AMMONIUM HYDROXIDE SOLN.	A DENSE, WHITE FUME WILL FORM IF
    SULFUR(ING 13)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY PLACE IN PROPERLY
    DESIGNED PRESSURE VESSELS.
Other Precautions:AVOID BREATHING GAS. DO NOT GET IN EYES, ON SKIN OR
    ON CLOTHING.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH/MSHA APPROVED FULL-FACE PIECE
    RESPIRATOR WITH ACID GAS CARTRIDGE. USE NIOSH/MSHA APPROVED
    POSITIVE PRESSURE SCBA FOR EMERGENCY OR OTHER CONDITIONS REQUIRING
    A HIGHER LEVEL OF PROTECTION.
Ventilation:USE LOCAL EXHAUST AS NEEDED TO MAINTAIN AIRBRONE EXPOSURE
    BELOW EXPOSURE LIMITS.
Protective Gloves:CHEMICAL RESISTANT GLOVES & BOOTS.
Eye Protection:CHEM WORK GOGG & FULL LENGTH FSHLD.
Other Protective Equipment:MAINTAIN A SINK, SAFETY SHOWER AND EYE WASH
    FOUNTAIN IN WORK AREA. HAVE OXYGEN READILY AVAILABLE. FULL PROT
    CLTHG/BOOTS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VAP PRESS:22.4 PSIA @ 0C. 49.1 PSIA @ 21.1C. 84.1 PSIA @ 37.3C. FIRE
    FIGHT PROC:PVNT RUNOFF & CONTAM OF WATER SOURCES. PERS WHO MAY HAVE
    BEEN EXPOSED TO CONTAM SMOKE SHOULD BE IMMED RELIEVED FROM DUTY  &
    CHECKED FOR SYMPS OF POISONING. THESE SHOULD NOT BE MISTAKEN FOR
    HEAT EXHAUSTION OR SMOKE INHAL. SEE FIRST AID PROC.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:14F,-10C
Melt/Freeze Pt:M.P/F.P Text:-104F,-76C
Vapor Pres:SUPP DATA
Vapor Density:2.26
Spec Gravity:1.36 @ 25C
Appearance and Odor:COLORLESS, COMPRESSED LIQUIFIED GAS/SUFFOCATING,
    PUNGENT ODOR

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AS A LIQ, REACTS VIOLENTLY W/ALKALI. REACTS W/WATER TO FORM CORROSIVE
    ACID. REACTS W/CHLORATES TO FORM UNSTABLE (ING 2)
Stability Condition to Avoid:ELEVATED TEMPERATURES CAN CAUSE CONTAINERS
    TO BURST.
Hazardous Decomposition Products:NONE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
    FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.